وصف السلعة
A power diode is a semiconductor device designed to convert alternating current into a unipolar one. For this, the diode is connected in series to the circuit of the alternating current source and the load. Power thyristor designed for regulation and switching of high currents. A thyristor can be considered as a kind of key that has two stable states: closed and open. A feature of the thyristor is that if you connect a positive voltage to the anode relative to the cathode, the thyristor will not conduct current, unlike the diode. Power diode module RUICHI, is a monolithic structure of two semiconductor diodes of the diode-diode type. The device is operated in DC and AC circuits with a load from 25 A to 800 A and a repetitive reverse impulse voltage up to 2200 V. High energy and thermal cyclic resistance and reliable operation of low-frequency diode modules for high current switching is achieved due to their design features and stable parameters of galvanic isolation. Thyristor module is a semiconductor power module that regulates and converts direct and alternating currents up to 100 amperes with a frequency of up to 500 Hz in circuits with voltages up to 1600 volts. We work out of stock and on order. Shipment from 2 days.
قراءة المزيد
تحقق من التوافر
حدد السعر
0
0
USD
أجل الحد الأدنى: 5 шт
القدرة على التسليم: 1000 шт/في الشهر
LLC RU Elktronics
مورد لم يتم التحقق منه
روسيا
معلومات الشحن
احسب واستكمل نقل البضائع الخاصة بك إلى أي مكان في العالم باستخدام Qoovee Logistics.
شحنة مضمونة في الوقت المحدد ودفع آمن احسب الشحن من Qooveeمنتجات مماثلة
LLC "KoFa"
روسيا
USD
8.0 - 10.5/шт
DuPont™ Tyvek® 500 Hooded Jumpsuit Expert.Material: TYVEK polyethylene - 100%, 41 g/m²Weight: less than 180g.Closure: zipperDesign features: 3-piece hood provides optimal fit and freedom of movement of the head. Elasticated hood, cuffs and hem, glued-in elastic waistband.Design allows for freedom of movement.Easy to grip with gloves, oversized zipper pull tab.Tyvek® material is made from high-density polyethylene fibers using fast twist technology for a superior fit. protective properties, durability and convenience. Tyvek® is a breathable material that is permeable to air and water vapor, but repels splashes of aqueous solutions and aerosols. A high degree of barrier protection against fine particles, viral and bacterial agents, fibers up to 1 micron in size, and at the same time extremely low linting of the material itself. Antistatic treatment. Silicone-free. Applications: medical, pharmaceutical, chemical, oil and gas, equipment repair, paint spraying, general cleaning and many others. Complies with TR CU 019/2011Color: white Size range: S, M, L, XL, XXL, XXXL
LLC "KoFa"
روسيا
USD
1.03/шт
1.03
Reusable lint-free cloth for clean rooms, laboratories, operating rooms, industries with increased requirements for cleanliness. • Used to remove excess sealant, mastic and other contaminants. • Due to the special structure of the knit, they have excellent absorbent properties and are able to capture dust particles. • Wipes do not contain silicone. • Convenient size and unique strength properties provide multiple use - at least 50 applications. • Maintain hostile environment for processing - solvents, acids, alcohols. • Sterilization is possible. (Autoclave, chemistry) Particularly strong and durable - technical cloth with overlaid edges. The standard size of 35x40 cm is convenient for any manipulations when cleaning or wiping equipment. Package options: 3 pcs. 5 pieces. 10 pieces. and more FORMULA FOR CALCULATION OF THE BENEFITS OF APPLICATION AND PURCHASE: 90r / 50 applications = 1rub 80 kopecks for 1 application!!!
Сельскохозяйственная тепличная система , гидропоники для выращивания клубники и не только . - 107265
Ibtisam
Астрахань, روسيا
حدد السعر
USD
0
0
Подносы для растений и водостоков, система выращивания гидропоники, стол для посадки теплиц, упакованный с деревянным корпусом и деревянным поддоном Такую систему для выращивания растений помогу заказать с Китая, беру только оптовые заказы .
Описание товара
Компания предоставляет теплицы, включая отопительное и охлаждающее оборудование, внутреннее/внешнее оборудование для затенения, стационарную/мобильную спринклерную систему, систему вентиляции, систему затенения, гидропонное оборудование и другие вспомогательные средства.
Компания обладает прочными научно-исследовательскими и опытными разработками, передовой концепцией дизайна, сильной инженерной и технической силой, богатым опытом строительства и безупречным послепродажным обслуживанием в овощных теплицах, саженцах и теплицах с цветами, саженцы теплиц, теплицы, теплицы, экологические рестораны и другие дизайн и строительство имеют богатый опыт. Теплица нашей компании изготовлена из оцинкованной стальной трубы, как каркас, с влагостойкостью, коррозионной стойкостью, устойчивостью к давлению, ветроустойчивостью, устойчивостью к снегу, длительным сроком службы и другими значительными преимуществами.
Подносы для растений и водостоков, система выращивания гидропоники, стол для посадки теплиц, упакованный с деревянным корпусом и деревянным поддоном
Такую систему для выращивания растений помогу заказать с Китая, беру только оптовые заказы .
Service Energy Ltd
Москва, روسيا
USD
14000.0 - 15000.0/шт
Selective Reclosure System
AR blocking for cable faults: prevents equipment damage from reclosing on permanent faults.
Dual data transmission: GSM + radio channel between modules.
Self-powered operation: no external power or maintenance.
Works with single- and double-fed OHL-cable lines
Overhead Power Line Diagnostics System (PLDS) is designed to remotely monitor the state of the wire without need for on-site visits by service personnel, and it signals the possibility of emergency situations in the early stages.
The system tracks the following parameters:
- wire operating parameters: temperature, current, sag angle, vibration amplitude and frequency;
- the occurrance, magnitude, and direction of short circuit current (with event oscillogram capture);
- ice load with weight display in kg;wire sag in meters (over roads, crossing, water bodies, etc.);
- wire break within the anchor section;
- wind loads on the wire, conductor galloping;
- detection of short circuit;
- prevention of wire breakage due to ice deposit formation;
- DLR;
- control of wire temperature, sag angle and distance between wire and obstacle.
BENEFITS:
- Reduction of time for indication of events;
- Reduction of time for finding of place of incident happened;
- Reduction of time for repair;
- Reduction of downtime;
- Reduction of cost of repair and downtime charges.
Customers:
- Electricity transmission and distribution operators (state and private)
- Industrial energy consumers with own OHL;
- Smart city/renewable energy projects.
ServiceEnergy Ltd offers FREE INDUSTRIAL TRIAL FOR POWER GRID COMPANIES!
To demonstrate the systems’ effectiveness, we offer:
- Free trial installation on a selected power line (including full technical support);
- Comprehensive analytics via web interface and Telegram alerts;
- Regulatory support.
Service Energy Ltd
Москва, روسيا
USD
14000.0 - 15000.0/шт
Dividing Automatics
PLDS-based divider automation system monitors short-circuit currents
flowing through the transmission line network, localizes the damaged
section and gives a command for switching on automatic reserve entry.
Overhead Power Line Diagnostics System (PLDS) is designed to remotely monitor the state of the wire without need for on-site visits by service personnel, and it signals the possibility of emergency situations in the early stages.
The system tracks the following parameters:
- wire operating parameters: temperature, current, sag angle, vibration amplitude and frequency;
- the occurrance, magnitude, and direction of short circuit current (with event oscillogram capture);
- ice load with weight display in kg;wire sag in meters (over roads, crossing, water bodies, etc.);
- wire break within the anchor section;
- wind loads on the wire, conductor galloping;
- detection of short circuit;
- prevention of wire breakage due to ice deposit formation;
- DLR;
- control of wire temperature, sag angle and distance between wire and obstacle.
BENEFITS:
- Reduction of time for indication of events;
- Reduction of time for finding of place of incident happened;
- Reduction of time for repair;
- Reduction of downtime;
- Reduction of cost of repair and downtime charges.
Customers:
- Electricity transmission and distribution operators (state and private)
- Industrial energy consumers with own OHL;
- Smart city/renewable energy projects.
ServiceEnergy Ltd offers FREE INDUSTRIAL TRIAL FOR POWER GRID COMPANIES!
To demonstrate the systems’ effectiveness, we offer:
- Free trial installation on a selected power line (including full technical support);
- Comprehensive analytics via web interface and Telegram alerts;
- Regulatory support.
Service Energy Ltd
Москва, روسيا
USD
250.0/шт
250.0
Explosion-Proof Access Control and Management System
The explosion-proof access control and management system is designed for reading identifiers, performing identification, controlling an external actuator, and generating an electrical signal to a component of the automated process control system to provide subsequent notification to the control panel about authorized access to the controlled area.
The operating principle of the system is based on a contactless (radio-frequency) method of reading a code from an electronic identifier, followed by an automatic comparison of the read code with the set of authorized codes and issuing an electrical signal to the external device.
The system includes a power-saving mode with automatic transition. Exit from the power-saving mode occurs when the reader panel is touched with an identifier (card) or when a control signal is received from an external device.
The system can operate either in standalone mode or in networked mode.
Overall dimensions (excluding cable): 150 × 85 × 70 mm
Weight: 1 kg
Explosion protection marking: 1Ex ib [ia Ga] IIB T5 Gb X
Degree of dust and moisture protection: IP54
Operating temperature range: −40…+60 °C
Guaranteed identifier reading distance:
— at 128 kHz operating frequency: 2 cm
— at 13 MHz operating frequency: 2 cm
Number of internal memory cells for identifier list storage: 256
Number of internal memory cells (event log): 65,536
DC supply voltage range: 4.5…30 V
Average current consumption in power-saving mode: 15 µA
Average current consumption during data reading: 50 mA
Average electrical power consumption: 0.05 W
Open collector output parameters:
— maximum switching voltage: 30 V
— maximum switching current: 0.5 A
Maximum data exchange rate via RS-485 interface: 57,600 baud
Maximum communication line length for RS-485 (using STP/FTP twisted pair): 100 m
Type and number of input/output interfaces for external devices:
— Discrete “open collector” output for actuator control: 1
— Discrete “open collector” output for signaling: 1
— Discrete input for deactivation of power-saving mode: 1
— Wired communication interface RS-485: 1
Service Energy Ltd
Москва, روسيا
USD
350.0/шт
350.0
Acoustic Sensor “NeuroAcustic – Ex”
The “NeuroAcustic – Ex” acoustic sensor is designed for use in vibroacoustic diagnostic systems for continuous monitoring of the condition and operational integrity of components and mechanisms at facilities responsible for the transportation and distribution of heat carriers, including natural gas.
The acoustic sensor is mounted on the monitored surface, detects sound waves through contact transmission, converts these sound waves into a standard audio signal, and transmits the signal to an external device.
The sensor can be used at industrial process facilities, including hazardous gas distribution and gas consumption facilities.
The acoustic sensor is designed to operate under the following environmental conditions:
Maximum ambient temperature: +110 °C
Minimum ambient temperature: −40 °C
The parameters of the intrinsically safe electrical circuits comply with the following values:
Input voltage (Ui), max: 12 V
Input current (Ii), max: 0.02 A
Input power (Pi), max: 0.1 W
Internal capacitance (Ci), max: 0.065 µF
Internal inductance (Li), max: 0.01 mH
Technical Specifications:
Overall dimensions: Ø27 × 35 mm
Weight: 0.3 kg
Degree of dust and moisture protection (IP rating): IP67
Supply voltage: 3–12 V
Current consumption: 5 mA
Operating frequency range: 100–6000 Hz
intended for:
- Thermal power plants, boiler houses, and gas distribution stations
- Oil and gas and chemical industry enterprises
- Companies specializing in equipment diagnostics
- Industrial safety and IIoT (Industrial Internet of Things) systems
Service Energy Ltd
Москва, روسيا
USD
390.0/шт
390.0
High Voltage Indicator
High Voltage Indicator "IVN Protection" - an additional safety measure for the electrician when working at a transformer substation.
The indicator is designed to provide visual and audible signaling of the presence of high voltage on live parts of high-voltage equipment operating at a line voltage of 6–10 kV and a frequency of 50 Hz.
The presence or absence of current flowing through the live parts does not affect the operation of the device.
The indicator is used to visually verify the results of switching operations on power lines, sections, and parts of electrical installations, as well as to warn maintenance personnel of the presence of voltage on electrical parts before carrying out scheduled or unscheduled work.
Design and Construction
The device consists of three capacitive voltage dividers (one per phase) and a visual and audible signaling panel.
Each capacitive divider and the indicator panel are housed in separate enclosures.
The divider housing is designed as a support insulator.
Both the dividers and the indicator panel are equipped with built-in connecting cables, which are used for installation and connection at the site.
Operation
The indicator provides simultaneous monitoring of the presence of nominal voltage on the live parts of all three phases of the electrical installation.
When nominal voltage is present on the monitored live parts, the indicator panel produces a steady light signal in three primary colors (yellow, green, and red), corresponding to the phase color coding of electrical installations.
Additionally, an audible alarm is activated when a high-voltage compartment door is opened, provided that the door is equipped with a position monitoring device such as a limit switch or reed door sensor.
The audible signal is generated only if nominal voltage is present on the monitored live part.
Optionally, the product package may include door position sensors.
Installation and Application
Mounting the indicator panel on the front panel of a switchgear cubicle or a prefabricated transformer substation makes the voltage indication more visible and attracts the attention of operating personnel before any work is carried out.
The indicator panel may also be installed in relay protection and automation (RPA) compartments, low-voltage switchboards, and similar enclosures.
Power Supply
The device is self-powered and does not require an external power source.
The indicator is energized directly from its connection to the live parts of the power line.
Technical Specifications:
Overall dimensions of the capacitive divider: 82 × 122.5 mm
Overall dimensions of the indicator panel: 114.4 × 59 × 34 mm
Length of the capacitive divider connecting cables: 300 mm
Length of the indicator panel connecting cables: 3000 mm
Weight of the capacitive divider: 0.7 kg
Weight of the indicator panel: 0.5 kg
Degree of dust and moisture protection (indicator panel): IP40
Number of capacitive dividers in the device: 3 pcs
Number of indicator panels in the device: 1 pc
Rated supply voltage (50 Hz): 6 or 10 kV
Maximum continuous operating voltage applied to the poles: 10 kV
Maximum test voltage: 42 kV
Minimum operating voltage: 0.6 kV
Service Energy Ltd
Москва, روسيا
USD
950.0/шт
950.0
Power Line Diagnostic System
Overhead Power Line Diagnostics System (PLDS) is designed to remotely monitor the state of the wire without need for on-site visits by service personnel, and it signals the possibility of emergency situations in the early stages.
The system tracks the following parameters:
- wire operating parameters: temperature, current, sag angle, vibration amplitude and frequency;
- the occurrance, magnitude, and direction of short circuit current (with event oscillogram capture);
- ice load with weight display in kg;wire sag in meters (over roads, crossing, water bodies, etc.);
- wire break within the anchor section;
- wind loads on the wire, conductor galloping;
- detection of short circuit;
- prevention of wire breakage due to ice deposit formation;
- DLR;
- control of wire temperature, sag angle and distance between wire and obstacle.
BENEFITS:
- Reduction of time for indication of events;
- Reduction of time for finding of place of incident happened;
- Reduction of time for repair;
- Reduction of downtime;
- Reduction of cost of repair and downtime charges.
Customers:
- Electricity transmission and distribution operators (state and private)
- Industrial energy consumers with own OHL;
- Smart city/renewable energy projects.
Service Energy Ltd offers FREE INDUSTRIAL TRIAL FOR POWER GRID COMPANIES!
To demonstrate the systems’ effectiveness, we offer:
- Free trial installation on a selected power line (including full technical support);
- Comprehensive analytics via web interface and Telegram alerts;
- Regulatory support.
System Specification:
Dimensions: 390x130x134 mm
Water resistant IP56
Weight: 3 kg
Communication channels: GSM 900/1800, radio channel (for close-located devices)
Power: from power line
Autonomic activity: minimum 2 hours after de-energized of lines via supercapacitors
Minimal amperage: 10A
Ambient temperature: -40 °C…+50 °C
Wire temperature measurement: -40 °C…+125 °C
Wire current measurement: 0-200 A
Sag angle measurement: 0-90 degrees
Wire vibration frequency: 1-1000 Hz
فئة الموردين
جميع الموردين في الفئة
المنتج:
المورد:
أوامر الحد الأدنى:
المديرية
قسم المبيعات:
قسم المبيعات:
قسم المبيعات:
المعلومات
أبلغ مدير أنك وجدت المنتج على Qoovee
جهات اتصال الموارد غير متاحة!
اكتب رسالة إلى المورد