Boiler KVm 1.25 ZP RPK

The design of the boiler KVm 1.25 with ZP RPK (KVm 1.44) includes:

    < li> high efficiency
  • fuel combustion efficiency
  • economy
  • compactness
  • reliability
  • ease of use
  • increased maintainability
  • ease of installation
  • no scale

The KVm 1.25 ZP RPK hot water boiler is characterized by high efficiency, which is achieved due to application of the following design solutions. The large volume of the combustion chamber ensures complete combustion of fuel, thereby reducing losses with mechanical underburning. Gas-tight design of the furnace and high-quality thermal insulation reduce heat losses through the walls of the boiler and the environment and exclude the suction of cold air into the boiler furnace. The developed convective heating surface provides a decrease in the temperature of flue gases from the boiler to 200 -180 ° C.

The use of modern technology of fuel combustion in the bed reduces losses with mechanical and chemical underburning of fuel. The hydraulic circuit in the boiler works in a counter-flow circuit and the convective package acts as an economizer. Numerous partitions installed in the boiler headers direct the coolant flow, excluding the occurrence of stagnant zones and local overheating of heating surfaces, high speeds and turbulization of the water flow minimize the formation of scale, KVm 1.25 boilers operate reliably without special measures for chemical water treatment.

Technical characteristics of the KVm 1.25 hot water boiler with ZP RPK

Hoşunuza gidebilir

Tedarikçiye sor
Tedarikçi:
"Узлегпром"
Bize yazın, çevrimiçiyiz!
Boiler power, Gcal / h (MW) < / td> 1.25 (1.44)
Heated area with a ceiling height of 3 m, m² 12500
Fuel, coal Kuznetskiy D Kharanorskiy B1
Net calorific value 5230 2720
Boiler efficiency, not less,% 83 76
Fuel consumption, kg / h 287 302
Equivalent fuel consumption, kg / h 215
Outgoing gas temperature azov, ° C Not more than 200
Consumption of working medium, m³ / h 50
Water temperature, ° C 70-95
Working medium pressure, MPa (kgf / cm²) 2.5-6
Boiler hydraulic resistance at a temperature difference of 25 ° C, MPa (kgf / cm²), no more than 0.007 (0.7)
Aerodynamic resistance, Pa (mm. water column), Combustion mirror area, m2 no more than 230
Combustion device KVm firebox ZP RPK
Overall dimensions of the boiler block with a firebox, no more
Length, mm 3400
Width, mm 1800
Height, mm 2350