Boiler plant Teploexpert, Irkutsk

Not approved icon Doğrulanmamış tedarikçi
Bu satıcı ile güvenli alışveriş yapın. Başvur
USD 1798.31/pcs 1798.31
KV 0.2 boiler The design of the KV 0.2 (KV 0.23) boiler includes: high efficiency < / li> fuel combustion efficiency economical compactness reliability ease of use increased maintainability ease of installation no scale Solid fuel hot water boiler KV 0.2 Gcal is characterized by high efficiency, which is achieved through the use of the following design solutions. The large volume of the combustion chamber ensures complete combustion of fuel, thereby reducing losses with mechanical underburning. The gas-tight design of the furnace and high-quality thermal insulation reduce heat losses through the walls of the heating steel boiler and the environment and exclude the suction of cold air into the boiler furnace. The developed convective heating surface ensures a decrease in the temperature of flue gases from the boiler to 200-180 ° C. The use of modern technology of fuel combustion in the bed reduces losses with mechanical and chemical underburning of fuel. The hydraulic circuit in an industrial steel heating boiler works according to the counterflow circuit and the convective package acts as an economizer. Numerous partitions installed in the collectors of a water boiler direct the flow of the coolant, eliminating the occurrence of stagnant zones and local overheating of heating surfaces. High velocities and turbulization of the water flow minimize the formation of scale, boilers operate reliably without special measures for chemical water treatment. Technical characteristics of the KV 0.2 hot water boiler Power of the hot water boiler, Gcal / h (MW) 0.2 (0.23) Heated area with a ceiling height of 3 m, m² 2000 Fuel, coal stone brown Net calorific value 5230 2720 Boiler efficiency, not less,% 80 73 Fuel consumption, kg / h < / td> 48 104 Equivalent fuel consumption, kg / h 35 < / td> Flue gas temperature, ° C Not more than 200 medium, m³ / h 8 Water temperature, ° C 70 -95 Working medium pressure , MPa (kgf / cm²) 2.5-6 Boiler hydraulic resistance at a temperature difference of 25 ° C, MPa ( kgf / cm²), no more than 0.05 (0.5) Aerodynamic resistance, Pa (mm.w. st.), Combustion mirror area, m2 no more than 30 Combustion device Grate Overall dimensions of the boiler block with a furnace, no more Length, mm 1050 Width, mm 1300 < / td> Height, mm 2200
USD 1700.22/pcs 1700.22
KV 0.15 boiler The design of the KV 0.15 (KV 0.17) boiler includes: high efficiency < / li> fuel combustion efficiency economical compactness reliability ease of use increased maintainability ease of installation no scale The hot water boiler KV 0,15 Gcal is characterized by high efficiency, which is achieved through the use of the following design solutions. The large volume of the combustion chamber ensures complete combustion of fuel, thereby reducing losses with mechanical underburning. Gas-tight design of the furnace and high-quality thermal insulation reduce heat losses through the walls of the boiler and the environment and exclude the suction of cold air into the boiler furnace. The developed convective heating surface ensures a decrease in the temperature of flue gases from the boiler to 200-180 ° C. The use of modern technology of fuel combustion in the bed reduces losses with mechanical and chemical underburning of fuel. The hydraulic circuit in a hot water boiler works according to the counterflow circuit and the convective package acts as an economizer. Numerous partitions installed in the boiler manifolds direct the coolant flow, eliminating the occurrence of stagnant zones and local overheating of heating surfaces. High velocities and turbulization of the water flow minimize the formation of scale, hot-water solid fuel boilers for long burning work reliably without special measures for chemical water treatment. Technical characteristics of the KV 0.15 Gcal boiler Power of a hot water boiler, Gcal / h (MW) 0.15 (0.17) Heated area with a ceiling height of 3 m, m² 1500 Fuel, coal stone brown Net calorific value 5230 2720 Boiler efficiency, not less,% 80 73 Fuel consumption, kg / h 45 76 Equivalent fuel consumption, kg / h 27 Flue gas temperature, ° C No more than 200 < td> Working medium flow rate, m³ / h 6 Water temperature, ° C 70-9 5 Working medium pressure, MPa (kgf / cm²) 2.5-6 Hydraulic resistance of the boiler at a temperature difference of 25 ° C, MPa (kgf / cm²), no more than 0.05 (0.5) < / tr> Aerodynamic resistance, Pa (mm.WC), Combustion mirror area, m2 no more than 80 Combustion device KVr firebox Overall dimensions of the boiler block with a firebox, no more < td colspan = "2"> Length, mm 950 Width, mm 1300 Height, mm 2050
USD 261.57/pcs 261.57
Main functions: automatic shutdown of the boiler when the pressure and temperature of the water leaving the boiler increase; manual remote shutdown of the boiler; light and sound signaling deviations of technological parameters from the norm and memorizing the root cause of the accident; remote start, stop and light indication of the operation of draft machines; control of temperature and pressure of water at the boiler outlet. The control panel of the KVr coal-fired hot water boiler has several versions: The control panel of the KVr boiler. Option 1 indicator lights and loud bang bell. Signals that the main parameters of the boiler operation are exceeded temperature and pressure; vacuum sensor in the furnace (flue); Boiler control panel KVr. Option 2 indicating devices with the display of the boiler operation parameter on the control panel display; temperature; vacuum sensor in the furnace (gas duct ); Boiler control panel KVR. Option 3 indicating devices with the display of the main parameters of the boiler operation on the control panel display; temperature and pressure; vacuum sensor in furnace (flue)
USD 26.65/pcs 26.65
Cast iron grates 880 * 220 are used in the furnaces of hot water and steam boilers of low power and are installed directly in the furnace part of the boiler on the ledges of the side walls and grate beams. Their purpose is to support the layer of solid fuel and improve the supply of oxygen to the combustion area. Openings are made in the grates 880x220, which are for supplying air to the fuel layer and the furnace, and for screening out the formed coal and ash into the ash pan. Stiffening ribs are made at the bottom of the grate. Grate grates are assembled from cast iron slab grates.
USD 65.94/pcs 65.94
The door of the combustion boiler Bratsk is installed in boilers Bratsk, hot water boilers KVr, KVm, steam boilers, as grooves for furnace mechanical furnaces.
USD 659.27/pcs 659.27
The smoke exhauster is a draft machine that is designed to remove flue gases - products of fuel combustion. Moving gases in the right direction is the primary task of the DN smoke exhauster. By creating the required draft in the boiler, the required performance of the boiler unit develops. Hot water and steam boilers are equipped with smoke exhausters. The smoke exhauster is designed for continuous operation with a long resource. It can be installed indoors or outdoors. The minimum temperature at which the smoke exhauster can operate is -30 ° C, the maximum one is up to 200 ° C. The smoke exhausters of right or left rotation are manufactured. If you look at the DN 3.5 / 1500 smoke exhauster from the side of the electric motor, and the rotation of the boiler smoke exhauster impeller will be counterclockwise, this will be considered counterclockwise rotation. Right-hand rotation - when the rotation of the impeller of the exhauster is performed in the clockwise direction. The main characteristics of the exhauster are performance and pressure. These parameters are controlled by an axial guide vane or a suction pocket with a gate. The suction pocket brings gases to the impeller blades more evenly and eliminates flow swirling, respectively, the efficiency of the smoke exhauster increases. The impeller is equipped with a hub to protect the bearings. The DN 3.5 / 1500 smoke exhauster can have a basic or simplified configuration, and they are also equipped with systems for efficient ash collection. The durability of the smoke exhausters is ensured by the thickened walls of the snail.
USD 283.37/pcs 283.37
The smoke exhauster is a draft machine that is designed to remove flue gases - products of fuel combustion. Moving gases in the right direction is the primary task of the DN smoke exhauster. By creating the required draft in the boiler, the required performance of the boiler unit develops. Hot water and steam boilers are equipped with smoke exhausters. The smoke exhauster is designed for continuous operation with a long resource. It can be installed indoors or outdoors. The minimum temperature at which the smoke exhauster can operate is -30 ° C, the maximum one is up to 200 ° C. The smoke exhausters of right or left rotation are manufactured. If you look at the DN 3.5 / 1500 smoke exhauster from the side of the electric motor, and the rotation of the boiler smoke exhauster impeller will be counterclockwise, this will be considered counterclockwise rotation. Right-hand rotation - when the rotation of the impeller of the exhauster is performed in the clockwise direction. The main characteristics of the exhauster are performance and pressure. These parameters are controlled by an axial guide vane or a suction pocket with a gate. The suction pocket brings gases to the impeller blades more evenly and eliminates flow swirling, respectively, the efficiency of the smoke exhauster increases. The impeller is equipped with a hub to protect the bearings. The DN 3.5 / 1500 smoke exhauster can have a basic or simplified configuration, and they are also equipped with systems for efficient ash collection. The durability of the smoke exhausters is ensured by the thickened walls of the snail.
USD 3008.09/pcs 3008.09
The hot water boiler KVr ​​0.7 Gcal is distinguished by high efficiency, which is achieved through the use of the following design solutions. The large volume of the combustion chamber ensures complete combustion of fuel, thereby reducing losses with mechanical underburning. Gas-tight design of the furnace and high-quality thermal insulation reduce heat losses through the walls of the boiler and the environment and exclude the suction of cold air into the boiler furnace. The developed convective heating surface ensures a decrease in the temperature of flue gases from the boiler to 200-180 ° C. The use of modern technology of fuel combustion in the bed reduces losses with mechanical and chemical underburning of fuel. The hydraulic circuit in a hot water solid fuel boiler for long burning works according to the counterflow circuit and the convective package acts as an economizer. Numerous partitions installed in the boiler headers direct the coolant flow, excluding the occurrence of stagnant zones and local overheating of heating surfaces, high speeds and turbulization of the water flow minimize the formation of scale, steel boilers operate reliably without special measures for chemical water treatment. Technical characteristics of the KVr 0.7 hot water boiler Boiler power, Gcal / h (MW) 0.6 (0.7) Heated area with a ceiling height of 3 m, m² 6000 < / td> Fuel, coal Kuznetskiy D Kharanorskiy B1 Lower heat combustion 5230 2720 Boiler efficiency, not less,% 82 73 Fuel consumption, kg / h 144 302 Equivalent fuel consumption, kg / h 108 Exhaust gas temperature, ° C 200 Consumption of working medium, m³ / h 24 Water temperature, ° C 70-95 Working medium pressure, MPa (kgf / cm² ) 0.3-0.7 (3-6) Boiler hydraulic resistance at a temperature difference of 25 ° C, MPa (kgf / cm²), no more than 0.07 (0.7) Aerodynamic resistance, Pa (mm.water .st.), Combustion mirror area, m2 no more than 300 Combustion device grate Overall dimensions of the boiler block with a firebox, no more Length, mm 2300 Width, mm 1450 Height, mm 1800
Kurumsal
Kategoriler: Adres:
Makine, ekipman ve aletler, Endustriyel ekipman ve makineler, Genel amaçlı ekipmanlar, Diğer ekipman ve makineler, Güç ve elektroteknik ekipman, Endüstriyel ekipman parçaları, Endüstriyel aletler Rusya, ул. Урицкого, д.8

Boiler plant Teploekspert, Irkutsk.

We produce hot water and steam boilers, furnaces, gas and liquid fuel boilers, modular boiler systems for fuel supply and slag removal, cyclones, draft machines and water treatment systems:
- hot water boilers KVR 0.15-KVR 4.0.

- coal-fired boilers with fire chambers TSHPM, TLPKh, ZP RPK, - KVm 0.8-KVm 4.0.
- hot water boilers for gas, diesel, fuel oil - Boiler KVA 0.47 - Boiler KVA 4.0

- steam boilers for gas, coal, wood, diesel, fuel oil, 300 kg / h, 500 kg / h, 700 kg / h, 1000 kg / h, KV-300 - 200,000 rubles, KV-500 - 390000 rubles, KV-700- 414000 rubles, KV-1000- 548000 rubles.
- wood-fired boilers KVR-0.23 KD, KVR-0.35 KD, KVR-0.47 KD, KVR-0.58 KD, KVR-0.7 KD, KZr-0.93 KD, KVr-1 , 28 cd.

- fire chambers TSHPM-0.8 - 300000 rubles, TSHPM-1.45-310000 rubles, TSHPM-1.5- 320 000 rubles, TSHPM-2.0 -330000 rubles, TSHPM-2.5 - 345000 rubles, spare parts of the furnace TShPM, TShPM gear rack segment, TShPM drive gear, TShPM support roller, TShPM lattice block, TShPM bunker, TShPM carriage, TShPM shura bar, -6500 rub, Ch 125 gearbox with engine. 3/1000, toothed rack TSHPM, pressure roller TShPM, pig-iron sleeve TShPM, firebox shield TShPM- 16000 rubles, steel section of the boiler Bratsk-6500 rubles, boiler water chamber Bratsk 37000 rubles, boiler nipple Bratsk

- fire chamber TLPH, fire chamber TLPH 1.1-4.25, fire chamber TLPH 1.1-3.5, fire chamber TLPH 1.1-3.0, fire chamber TLPH 1.4-4.0, fire chamber TLPH 1.87- 3.0, Fire chamber TLPH 1.87-4.25, Fire chamber TLPH 1.87-5.6, Fire chamber TLPH 1.87-6.5, Fire chamber TLP-0.8-3.32, Fire chamber TLP-0, 8-3.0 . Sprocket 23.5769.001, Gear wheel 23.5701.004, Half coupling 00.56.84.004, Rail 00.4260.001, Seal, Grate 23.1603.006 (081), Grate 23.1603.007 (084), Grate 23.1603.008 (080), Gearbox RPG- 1, The pin of the grate blade TLH, Canvas firebox TLH complete

- fire chambers TLZM Fire chamber TLZM 1.87 / 2.4, Fire chamber TLZM 1.87 / 3.0, Fire chamber TLZM 2.7 / 3.0, Fire chamber TLZM 2.7 / 4.0, grate 00.1603.032-01 ( T 24.06.001-01), grate 00.1603.032 (T 24.06.001), grate 00.1603.057 (T 24.06.004), grate 00.1603.058 (T 24.06.003, grate 00.1603.035 (T 328.01.03.00. 002), grate 00.1603.036 (T 328.01.03.00.001), pin 00.4101.084 (T 24.03.003, pin 00.4101.084-01 (T 68.03.001), full grate blade TLZM

- TCHZM fire chamber, TCHZM fire chamber 2.7-4.0, TCHZM fire chamber 2.7-5.6, TCHZM fire chamber 2.7-6.5, TCHZM fire chamber 2.7-8.0,

grate 00.1603.056 (6.30.26, grate 00.1603.038 (Т 220.13.001), holder 00.7003.004 (Т 220.13.002), holder 00.7003.005 (Т 220.13.003), holder 00.7003.006 (Т 220.13. 004), holder 00.7003.002 (T 9.05.002), holder 00.7003.001 (T 9.05.001), holder 00.7003.003 (6.30.2, roller roller 00.4609.003 (6.30.25)

- mechanical spreaders ZP-400, ZP-600, PMZ-400, PMZ-600. Spare parts for spreaders Sprocket 00.5786.008 (T67.00.066 m2), bearing housing 00.6927.007-00.1321.001 (T67.19.013M2) bearing cover 00.5081.001 (T67.19.008), bearing cover 00.6927.006, rotor blade (400 ) 00.1494.021-02 (Т 67.01.001М2-01), rotor blade (600) 00.1494.021 (Т 67.01.001М2) 600 tray 00.1601.022 (Т 67.00.001) 400 tray 00.1601.022-02 ( Т 67.00.001-01), regulating plate 00.1601.025 (Т67.24.001 М 2), regulating plate 00.1601.025-01 (67.24.001 М2-01), ZP-400 frame 00.1601.020-01 (Т 67.00. 005 M-1), frame ZP-600 00.1601.020 (T 67.00.005 M-2), Pulse variator T67.33.000 SB.

- battery cyclones BTs 2, BTs 2-4- (3 + 2), BTs 2-5- (3 + 2, BTs 2-5- (4 + 2), BTs 2-6- (4 + 2), BTs 2-6- (4 + 3), BC 2-7- (5 + 3).

- Battery cyclones BTs-259. BTs-259- (3x2), BTs-259- (3x3), BTs-259- (4x3), BTs-259- (4x4) rub, BTs-259- (4x5), BTs-259- (6x4), BTs -259- (6x5), BTs-259- (6x6), BTs-259- (6x7), BTs-259- (6x8).

Tedarikçiye sor
Tedarikçi:
"Узлегпром"
Bize yazın, çevrimiçiyiz!