Boiler plant Teploexpert, Irkutsk

Not approved icon Not verified supplier
Make a safe deal with this supplier. Apply
USD 7760.0/pcs 7760.0
Gas steam generator 1000 kg Industrial gas steam generator is designed to generate high pressure steam 0.3 - 0.8 MPa (8.0 kgf / cm2) and temperatures up to 170 ° C. Brand - boiler E 1.0-0.9 Gn. If you need low pressure steam according to the technology, the Boiler Plant produces a gas steam boiler KV 1000 with a pressure of up to 0.07 MPa and a temperature of up to 115 ° C . Technical characteristics of 1000 kg gas steam generator Name Gas steam generator 700 kg Brand Steam boiler E 0.7-0.9 H Gas steam generator capacity, MW (Gcal / h) 0.52 (0.45) Power, kW 520 Steam capacity, kg / h 700 Working medium pressure, MPa (kgf / cm2) 0,8(8,0) Steam temperature, no more, ° C 170 Fuel type Gas Net heat fuel combustion, kcal / kg 812 0 Fuel consumption, kg / h 62 Flue gas temperature, ºС 180 Heating capacity regulation range,% 40-100 Steam generator efficiency, not less,% 90 Dimensions of the boiler block, without chimney and burner Length, mm 3920 < td> Width, mm 2290 Height, mm 2350 < td colspan = "2"> Mass of the gas steam generator, kg 3270
USD 5896.29/pcs 5896.29
Solid fuel steam generator 500 kg The industrial solid fuel steam generator is designed to generate high pressure steam 0.3 - 0.8 MPa (up to 8.0 kgf / cm2) and temperatures up to 170 ° C. Brand - boiler E 0.5-0.9 R. If you need low pressure steam according to the technology, the Boiler Plant produces a solid fuel steam boiler KV 500 with a pressure of up to 0.07 MPa and a temperature of up to 115 ° C . Technical characteristics of a solid fuel steam generator 500 kg Name Solid fuel steam generator 500 kg Brand Steam boiler E 0.5 -0.9 Р Power of a solid fuel steam generator, MW (Gcal / h) 0.37 (0.32) Power, kW 370 Steam capacity, kg / h 500 Working medium pressure, MPa (kgf / cm2) 0.8 (0.8) Temperature steam, no more, ° C 170 Fuel type Coal Lower heat of combustion of fuel, kcal / kg 5230 Fuel consumption, kg / h 45.3 Consumption fuel, kg / h 97.8 Exhaust gas temperature, ºС 180 Range of regulation of heat output,% 40-100 Efficiency of a solid fuel steam generator, not less,% 81 Boiler block dimensions, without chimney and burner Length, mm 3310 Width, mm 2290 Height, mm 2350 Mass of solid fuel steam generator, kg 2900
USD 3574.83/pcs 3574.83
Solid fuel steam generator 300 kg Industrial solid fuel steam generator is designed to generate high pressure steam 0.3 - 0.8 MPa (up to 8.0 kgf / cm2) and temperatures up to 170 ° C. Brand - boiler E 0.3-0.9 R. If you require low pressure steam according to the technology, the Boiler Plant produces a solid fuel steam boiler KV 300 with a pressure of up to 0.07 MPa and a temperature of up to 115 ° C. Technical characteristics of a solid fuel steam generator 300 kg Name Solid fuel steam generator 300 kg steam Brand Steam boiler Е 0,3-0,9 Р Power of solid fuel steam generator, MW (Gcal / h) 0.22 (0.19) Power, kW 220 Steam capacity, kg / h 300 Working medium pressure, MPa (kgf / cm2) 0.8 (8.0) Steam temperature, not more, ° C 170 Fuel type Coal Lower heat of combustion of fuel, kcal / kg 5230 Fuel consumption, kg / h 45.3 Equivalent fuel consumption, kg / h 97.8 Flue gas temperature, ºС 180 Heat output regulation range,% 40-100 Efficiency of a solid fuel steam generator, not less,% 81 Overall dimensions of a solid fuel steam generator 300 kg Length, mm 2650 Width, mm 1840 Height, mm 2010 Mass of solid fuel steam generator, kg < / td> 1250
USD 9298.92/pcs 9298.92
Liquid fuel and gas boilers KVa are smooth-tube, the movement of the coolant takes place in a welded pipe system consisting of collectors and pipes of furnace and convective panels welded into them. Fuel entering through the burner device burns in the boiler combustion chamber, hot gases wash the tube surface of the combustion chamber, then enter the convective packets and through the flue duct are thrown into the chimney. The KVa boiler unit is installed on a frame with supports and has a frame with heat-insulating materials, sheathed with steel sheet. An explosion valve is installed in the rear screen of the furnace, which protects the boiler structure from destruction in the event of excessive pressure in the furnace. The burner is mounted in the front part of the combustion chamber. The front plate is fixed to the boiler with hinges and acts as a hatch, which allows access to the boiler combustion chamber for inspection and repair work without disassembling the front lining and insulation. The operation of the KVa hot water boiler is carried out with various models of burners that supply fuel to the combustion chamber, where it is burned and the coolant is heated. The block burner burns fuel, changes the combustion mode, maintains the water temperature in the boiler circuit up to 115 ° C. The temperature range of the water in the boiler circuit is set on the control panel. When the extreme values ​​are reached, the burner is switched on and off automatically. This mode ensures reliable and economical operation of the boiler. Technical characteristics of KVA boilers with a capacity of 3.0 MW Indicator name KVa 3.0 boiler Power of a hot water boiler, MW (Gcal / h) 3.0 (2.6) Fuel Gas Fuel oil Diesel Net calorific value, kcal / h 8120 9260 10200 Boiler efficiency, not less,% 91 , 5 87.5 91.5 Fuel consumption, nm3 / h (kg / h) 350 321 279 Flue gas temperature, no more, ° С 200 220 220 Working regulation range,% 40 -100 Water flow rate, m3 / h 104 Working water pressure, MPa (kgf / cm) 2 0.3-0.6 (3-6) Hydraulic resistance of the boiler, no more, MPa (kgf / cm) 2 0.15 (1 , 5) Water temperature, ° С 70-95 (90-115) Combustion chamber depth, mm 3765 Equivalent diameter, mm 1650 Length, mm 4900 Width , mm 2300 Height, mm 2950
USD 2343.26/pcs 2343.26
Liquid fuel and gas boilers KVa are smooth-tube, the movement of the coolant takes place in a welded pipe system consisting of collectors and pipes of furnace and convective panels welded into them. Fuel entering through the burner device burns in the boiler combustion chamber, hot gases wash the tube surface of the combustion chamber, then enter the convective packets and through the flue duct are thrown into the chimney. The KVa boiler unit is installed on a frame with supports and has a frame with heat-insulating materials, sheathed with steel sheet. An explosion valve is installed in the rear screen of the furnace, which protects the boiler structure from destruction in the event of excessive pressure in the furnace. The burner is mounted in the front part of the combustion chamber. The front plate is fixed to the boiler with hinges and acts as a hatch, which allows access to the boiler combustion chamber for inspection and repair work without disassembling the front lining and insulation. The operation of the KVa hot water boiler is carried out with various models of burners that supply fuel to the combustion chamber, where it is burned and the coolant is heated. The block burner burns fuel, changes the combustion mode, maintains the water temperature in the boiler circuit up to 115 ° C. The temperature range of the water in the boiler circuit is set on the control panel. When the extreme values ​​are reached, the burner is switched on and off automatically. This mode ensures reliable and economical operation of the boiler. Technical characteristics of 0.4 MW KVA boilers Indicator name KVa 0.4 boiler Power of a hot water boiler, MW (Gcal / h) 0.4 (0.34) Fuel < / td> Gas Fuel oil Diesel Net calorific value, kcal / h 8120 9260 10200 Boiler efficiency, not less,% 91 85 91 Fuel consumption, nm3 / h (kg / h) 46 4337 Flue gas temperature, no more, ° С 200 220 220 Range of working regulation,% 40-100 Water consumption, m3 / h 14 Working water pressure, MPa (kgf / cm) 2 0.3-0.6 (3-6) Hydraulic resistance of the boiler, no more, MPa (kgf / cm) 2 0.07 (0.7) Water temperature, ° С 70-95 (90-115) Combustion chamber depth, mm 1710 Equivalent diameter, mm 700 Length, mm 2500 Width, mm 1200 Height, mm 1900 < / table>
USD 4926.29/pcs 4926.29
Construction and arrangement: the presence of 2 loading doors; a large volume of the combustion chamber, for a one-time loading of a large volume of low-calorie wood fuel; the presence of a rotary chamber at the outlet of the boiler combustion chamber in front of the convective beam, which increases the afterburning zone of light and small fuel particles captured by the flow of exhaust gases. In wood-fired boilers with a capacity of 1.1 Gcal, high efficiency is achieved, by applying the following design solutions. The large volume of the combustion chamber ensures complete combustion of fuel, thereby reducing losses with mechanical underburning. Gas-tight design of the furnace and high-quality thermal insulation reduce heat losses through the walls of the boiler and the environment and exclude the suction of cold air into the boiler furnace. The developed convective heating surface ensures a decrease in the temperature of flue gases from the boiler to 200-180 ° C. The use of modern technology of fuel combustion in the bed reduces losses with mechanical and chemical underburning of the fuel. The hydraulic circuit in the wood-fired boiler works according to the counterflow circuit and the convective package acts as an economizer. Numerous partitions installed in the boiler manifolds direct the coolant flow, eliminating the occurrence of stagnant zones and local overheating of heating surfaces. High velocities and turbulization of the water flow minimize the formation of scale, hot water boilers operate reliably without special water treatment. The water heating solid fuel boiler on wood 1,1 is made of a smooth-tube, horizontal layout, consists of two blocks: furnace and convective ... A cast-iron grate is installed in the firebox, at the front there are two cast-iron loading doors. The firebox of hot water boilers is shielded with gas-tight panels. The convective block consists of convective sections. Convective pipes are welded into the risers. The horizontal pipes of the convection sections in the convection block are staggered. The boilers have two convection blocks, separated by a gas-tight partition that guides the movement of gases. The convective heating surface of a hot water boiler consists of packages that can be easily dismantled during repairs even in a confined space (when the width of the passages between the boilers is one meter). In the lower part of the convective packages there is an ash bin with a manhole for cleaning from ash and soot and inspecting the pipes of the convective bundle. Hot water boilers have thermal insulation and a removable decorative casing. The lining of the boilers is made of mineral mats and refractory wire, the cladding is made of galvanized or sheet steel. Hot water boilers KV-1,1 are easy to maintain and repair due to the presence of hatches for inspection and cleaning of convective packages. To ensure safe operating conditions and design operating modes, the wood-fired hot water boiler 1,1 is equipped with safety and shut-off and control valves, instrumentation and safety devices. Shut-off valves are used to drain water from the boiler into the heating network, supply return water to the boiler, drain water from the boiler, for periodic blowdown and removal of sludge. Instrumentation, thermometers and pressure gauges ensure the measurement of pressure and temperature at the inlet and outlet of water from hot water boilers. Technical characteristics of the boiler 1,1 Gcal for wood fuel Name Wood-fired hot water boiler KVr-1,1 KD Power of a hot water boiler, MW (Gcal / h) 1.28 (1.1) Heated area with a ceiling height of 3 m2, m 11000 Working medium consumption, m³ / h 44 Working water pressure, MPa (kgf / cm²) 0.6 (6) Water temperature, ° C 70-95 Heating surface, m² 41 Hydraulic resistance, MPa (kgf / cm²) Not more than 0.02 (0.2) Fuel ( design) Firewood Qir = 2000 kcal / kg Boiler efficiency on design fuel,% Not less than 75 Flue gas temperature, ° C Not more than 210 Aerodynamic resistance, Pa (mm. water. st.) 80 Overall dimensions of the boiler, no more < td> Length, mm 3330 Width, mm 9050 < td> Height, mm 2200 Total weight of the boiler of a wood-fired hot water boiler, kg 3800
USD 3923.6/pcs 3923.6
Construction and arrangement: the presence of 2 loading doors; a large volume of the combustion chamber, for a one-time loading of a large volume of low-calorie wood fuel; the presence of a rotary chamber at the outlet of the boiler combustion chamber in front of the convective beam, which increases the afterburning zone of light and small fuel particles captured by the flow of exhaust gases. In wood-fired boilers with a capacity of 0.6 Gcal, high efficiency is achieved, by applying the following design solutions. The large volume of the combustion chamber ensures complete combustion of fuel, thereby reducing losses with mechanical underburning. Gas-tight design of the furnace and high-quality thermal insulation reduce heat losses through the walls of the boiler and the environment and exclude the suction of cold air into the boiler furnace. The developed convective heating surface ensures a decrease in the temperature of flue gases from the boiler to 200-180 ° C. The use of modern technology of fuel combustion in the bed reduces losses with mechanical and chemical underburning of the fuel. The hydraulic circuit in the wood-fired boiler works according to the counterflow circuit and the convective package acts as an economizer. Numerous partitions installed in the boiler manifolds direct the coolant flow, eliminating the occurrence of stagnant zones and local overheating of heating surfaces. High speeds and turbulization of the water flow minimize the formation of scale, hot water boilers work reliably without special water treatment. The 0.6 solid fuel boiler is made of a smooth-tube, horizontal layout, consists of two blocks: furnace and convective ... A cast-iron grate is installed in the firebox, at the front there are two cast-iron loading doors. The firebox of hot water boilers is shielded with gas-tight panels. The convective block consists of convective sections. Convective pipes are welded into the risers. The horizontal pipes of the convection sections in the convection block are staggered. The boilers have two convection blocks, separated by a gas-tight partition that guides the movement of gases. The convective heating surface of a hot water boiler consists of packages that can be easily dismantled during repairs even in a confined space (when the width of the passages between the boilers is one meter). In the lower part of the convective packages there is an ash bin with a manhole for cleaning from ash and soot and inspecting the pipes of the convective bundle. Hot water boilers have thermal insulation and a removable decorative casing. The lining of the boilers is made of mineral mats and refractory wire, the cladding is made of galvanized or sheet steel. Hot water boilers KV-0.6 are easy to maintain and repair due to the presence of hatches for inspection and cleaning of convective packages. To ensure safe operating conditions and design operating modes, a wood-fired hot water boiler 0.6 is equipped with safety and shut-off and control valves, instrumentation and safety devices. Shut-off valves are used to drain water from the boiler into the heating network, supply return water to the boiler, drain water from the boiler, for periodic blowdown and removal of sludge. Control and measuring devices, thermometers and manometers provide measurement of pressure and temperature at the inlet and outlet of water from hot water boilers. Technical characteristics of the boiler 0.6 Gcal for wood fuel Name Wood-fired hot water boiler KVr-0.6KD < / tr> Power of a hot water boiler, MW (Gcal / h) 0.6 (0.7) < tr> Heated area with a ceiling height of 3 m2, m 6000 Working medium flow rate, m3 / h 24 Working water pressure, MPa (kgf / cm²) 0.6 (6) < td> Water temperature, ° C 70-95 Heating surface, m2 27 Hydraulic resistance, MPa (kgf / cm²) Not more than 0.02 (0.2) Fuel (design ) Firewood Qir = 2000 kcal / kg Boiler efficiency on project fuel,% Not less than 75 < td> Flue gas temperature, ° C Not more than 210 Aerodynamic resistance, Pa (mm. water. st.) 67 Overall dimensions of the boiler, no more < td> Length, mm 2290 Width, mm 7050 < td> Height, mm 2100 Total weight of the boiler of a wood-fired hot water boiler, kg 2800
USD 2539.44/pcs 2539.44
Construction and arrangement the presence of 2 loading doors; a large volume of the combustion chamber, for a one-time loading of a large volume of low-calorie wood fuel; < / li> the presence of a rotary chamber at the outlet of the boiler combustion chamber in front of the convective beam, increasing the afterburning zone of light and fine fuel particles captured by the flow of exhaust gases. In wood-fired boilers with a power of 0, 3 Gcal, high efficiency is achieved due to the application of the following design solutions. The large volume of the combustion chamber ensures complete combustion of fuel, thereby reducing losses with mechanical underburning. Gas-tight design of the furnace and high-quality thermal insulation reduce heat losses through the walls of the boiler and the environment and exclude the suction of cold air into the boiler furnace. The developed convective heating surface ensures a decrease in the temperature of flue gases from the boiler to 200-180 ° C. The use of modern technology of fuel combustion in the bed reduces losses with mechanical and chemical underburning of the fuel. The hydraulic circuit in the wood-fired boiler works according to the counterflow circuit and the convective package acts as an economizer. Numerous partitions installed in the boiler manifolds direct the coolant flow, eliminating the occurrence of stagnant zones and local overheating of heating surfaces. High velocities and turbulization of the water flow minimize the formation of scale, hot water boilers work reliably without special water treatment. The hot water solid fuel boiler on wood 0.3 is made of a smooth-tube, horizontal layout, consists of two blocks: a furnace and a convective ... A cast-iron grate is installed in the firebox, at the front there are two cast-iron loading doors. The firebox of hot water boilers is shielded with gas-tight panels. The convective block consists of convective sections. Convective pipes are welded into the risers. The horizontal pipes of the convection sections in the convection block are staggered. The wood-fired boiler 0.3 has two convection blocks, separated by a gas-tight partition that guides the movement of gases. The convective heating surface of a hot water boiler consists of packages that can be easily dismantled during repairs even in a confined space (when the width of the passages between the boilers is one meter). In the lower part of the convective packages there is an ash bin with a manhole for cleaning from ash and soot and inspecting the pipes of the convective bundle. Hot water boilers have thermal insulation and a removable decorative casing. The lining of the boilers is made of mineral mats and refractory wire, the cladding is made of galvanized or sheet steel. The KV-0.3 hot water boilers are easy to maintain and repair due to the presence of hatches for inspection and cleaning of convective packages. To ensure safe operating conditions and design operating modes, the boiler is equipped with safety and shut-off and control valves, instrumentation and safety devices. Shut-off valves are used to drain water from the boiler into the heating network, supply return water to the boiler, drain water from the boiler, for periodic blowdown and removal of sludge. Control and measuring devices, thermometers and manometers provide measurement of pressure and temperature at the inlet and outlet of water from water heating boilers. Technical characteristics of the boiler 0.3 Gcal for wood fuel Name Wood-fired hot water boiler KVr-0.3KD < / tr> Power of a hot water boiler, MW (Gcal / h) 0.35 (0.3) < tr> Heated area with a ceiling height of 3 m2, m 3000 Working medium consumption, m³ / h 12 Working water pressure, MPa (kgf / cm²) 0.6 (6) < td> Water temperature, ° C 70-95 Heating surface, m² 17 Hydraulic resistance, MPa (kgf / cm²) Not more than 0.02 (0.3) Fuel (design ) Firewood Qir = 2000 kcal / kg Boiler efficiency on project fuel,% Not less than 75 Flue gas temperature, ° C Not more than 200 Aerodynamic resistance, Pa (mm. water. st.) 51 Overall dimensions of the boiler, no more < td> Length, mm 1940 Width, mm 1300 < td> Height, mm 2050 Total weight of the boiler of a wood-fired hot water boiler, kg 1500
USD 9264.04/pcs 9264.04
Boiler KVm 1.6 with TSPM The design of the boiler KVm 1.6 with TSPM (KVm 1.86) includes: high efficiency fuel combustion efficiency economic efficiency compactness reliability ease of use increased maintainability ease of installation lack of scale The KVm 1.6 hot water boiler with TShPM-2.0 is characterized by high efficiency, which is achieved through the use of the following design solutions. The large volume of the combustion chamber ensures complete combustion of fuel, thereby reducing losses with mechanical underburning. Gas-tight design of the furnace and high-quality thermal insulation reduce heat losses through the walls of the boiler and the environment and exclude the suction of cold air into the boiler furnace. The developed convective heating surface ensures a decrease in the temperature of flue gases from the boiler to 180-200 ° C. The use of modern technology of fuel combustion in a bed reduces losses with mechanical and chemical underburning of fuel. The hydraulic circuit in the boiler works according to the counterflow circuit and the convective package acts as an economizer. Numerous partitions installed in the boiler collectors direct the flow of the coolant, eliminating the occurrence of stagnant zones and local overheating of heating surfaces, high speeds and turbulization of the water flow minimize the formation of scale, KVm 1.6 boilers operate reliably without special measures for chemical water treatment. Technical characteristics of a hot water boiler KVm 1.6 Gcal with TShPM-2.0 Power of a hot water boiler, Gcal / h (MW) 1.6 (1.86) Heated area with a ceiling height of 3 m, m² 12500 Fuel, coal Kuznetskiy D Kharanorskiy B1 Net calorific value 5230 2720 Boiler efficiency, not less,% 83 77 Fuel consumption, kg / h 370 764 Equivalent fuel consumption, kg / h 276 Outgoing temperature their gases, ° C Not more than 550 Working medium consumption, m³ / h 64 Water temperature, ° C 70-95 < td> Working medium pressure, MPa (kgf / cm²) 3-6 Boiler hydraulic resistance at a temperature difference of 25 ° C , MPa (kgf / cm²), no more than 0.07 (0.7) Aerodynamic resistance, Pa (mm water column), Combustion mirror area, m2 no more than 550 Combustion device KVr RPK furnace Gabaoite dimensions of the boiler block, no more < tr> Length, mm 4500 Width, mm 1950 Height, mm 3100
USD 8719.1/pcs 8719.1
Boiler KVm 1.25 ZP RPK The design of the boiler KVm 1.25 with ZP RPK (KVm 1.44) includes: < li> high efficiency fuel combustion efficiency economy compactness reliability ease of use increased maintainability ease of installation no scale The KVm 1.25 ZP RPK hot water boiler is characterized by high efficiency, which is achieved due to application of the following design solutions. The large volume of the combustion chamber ensures complete combustion of fuel, thereby reducing losses with mechanical underburning. Gas-tight design of the furnace and high-quality thermal insulation reduce heat losses through the walls of the boiler and the environment and exclude the suction of cold air into the boiler furnace. The developed convective heating surface provides a decrease in the temperature of flue gases from the boiler to 200 -180 ° C. The use of modern technology of fuel combustion in the bed reduces losses with mechanical and chemical underburning of fuel. The hydraulic circuit in the boiler works in a counter-flow circuit and the convective package acts as an economizer. Numerous partitions installed in the boiler headers direct the coolant flow, excluding the occurrence of stagnant zones and local overheating of heating surfaces, high speeds and turbulization of the water flow minimize the formation of scale, KVm 1.25 boilers operate reliably without special measures for chemical water treatment. Technical characteristics of the KVm 1.25 hot water boiler with ZP RPK Boiler power, Gcal / h (MW) < / td> 1.25 (1.44) Heated area with a ceiling height of 3 m, m² 12500 Fuel, coal Kuznetskiy D Kharanorskiy B1 Net calorific value 5230 2720 Boiler efficiency, not less,% 83 76 Fuel consumption, kg / h 287 302 Equivalent fuel consumption, kg / h 215 Outgoing gas temperature azov, ° C Not more than 200 Consumption of working medium, m³ / h 50 Water temperature, ° C 70-95 Working medium pressure, MPa (kgf / cm²) 2.5-6 Boiler hydraulic resistance at a temperature difference of 25 ° C, MPa (kgf / cm²), no more than 0.007 (0.7) Aerodynamic resistance, Pa (mm. water column), Combustion mirror area, m2 no more than 230 Combustion device KVm firebox ZP RPK Overall dimensions of the boiler block with a firebox, no more Length, mm 3400 Width, mm 1800 Height, mm 2350
USD 2833.71/pcs 2833.71
Котел КВм 0,6В конструкции котла КВм 0,6 (КВм 0,7) заложено:высокий КПДэффективность сжигания топливаэкономичностькомпактностьнадежностьудобство эксплуатацииповышенная ремонтопригодностьпростота монтажабезнакипностьТвердотопливный водогрейный котел КВм 0,6 ГКал под механическую топку отличает высокий КПД, что достигается за счет применения следующих конструктивных решений. Большой объем топочной камеры обеспечивает полное выгорание топлива, снижая тем самым потери с механическим недожогом. Газоплотное исполнение топки и качественная теплоизоляция снижают потери тепла через стенки котла и окружающую среду и исключают присосы холодного воздуха в топку котла. Развитая конвективная поверхность нагрева обеспечивает снижение температуры уходящих газов из котла до 200 - 180 °С.Применение современной технологии сжигания топлива в слое снижает потери с механическим и химическим недожогом топлива. Гидравлическая схема в водогрейном твердотопливном котле длительного горения работает по схеме противотока и конвективный пакет выступает в роли экономайзера. Многочисленные перегородки, установленные в коллекторах котла, направляют поток теплоносителя, исключая возникновение застойных зон и локальный перегрев поверхностей нагрева, высокие скорости и турбулизация потока воды максимально снижают образование накипи, котлы КВм с шурующей планкой надежно работают без специальных мероприятий по химводоподготовки.Технические характеристики водогрейного котла КВм 0,6Мощность водогрейного котла, Гкал/ч (МВт)0,52 (0,6)Отапливаемая площадь при высоте потолка 3 м, м²6000Топливо, угольКузнецкий ДХаранорский Б1Низшая теплота сгорания52302720КПД котла, не менее, %8273Расход топлива, кг/ч124302Расход условного топлива, кг/ч93Температура уходящих газов, °CНе более 200Расход рабочей среды, м³/ч21Температура воды, °C70-95Давление рабочей среды, МПа (кгс/cм²)2,5-6Гидравлическое сопротивление котла при перепаде температур 25°C, МПа (кгс/cм²),не более 0,007 (0,7)Аэродинамическое сопротивление, Па (мм.вод.ст.), Площадь зеркала горения, м²не более 220Топочное устройствотопка РПКГабаритные размеры котельного блока с топкой, не более Длина, мм2200Ширина, мм1450Высота, мм2000
USD 2583.03/pcs 2583.03
KV 0.4 boiler The design of the KV 0.4 (KV 0.47) boiler includes: high efficiency < / li> fuel combustion efficiency economical compactness reliability ease of use increased maintainability ease of installation no scale Solid fuel hot water boiler KV 0.4 Gcal is characterized by high efficiency, which is achieved through the use of the following design solutions. The large volume of the combustion chamber ensures complete combustion of fuel, thereby reducing losses with mechanical underburning. Gas-tight design of the furnace and high-quality thermal insulation reduce heat losses through the walls of the boiler and the environment and exclude the suction of cold air into the boiler furnace. The developed convective heating surface provides a decrease in the temperature of flue gases from the boiler to 200 -180 ° C. The use of modern technology of fuel combustion in the bed reduces losses with mechanical and chemical underburning of fuel. The hydraulic circuit in the hot water boiler works according to the counterflow circuit and the convective package acts as an economizer. Numerous partitions installed in the boiler manifolds direct the coolant flow, eliminating the occurrence of stagnant zones and local overheating of heating surfaces. High speeds and turbulization of the water flow minimize the formation of scale, the boilers operate reliably without special measures for chemical water treatment. Technical characteristics of the KV 0.4 hot water boiler Name Boiler 0.4 Power of a hot water boiler, Gcal / h (MW) 0.4 (0.47) < / tr> Heated area with a ceiling height of 3 m, m² 4000 Fuel, coal stone brown Net calorific value 5230 2720 Boiler efficiency, not less,% 82 74 Fuel consumption , kg / h 94.7 205 Equivalent fuel consumption, kg / h 69 Flue gas temperature, ° C No more than 200 < tr> Consumption of working medium, m³ / h 16 Water temperature, ° C 70-95 < tr> Working medium pressure, MPa (kgf / cm²) 3.0-6.0 Hydraulic resistance boiler at a temperature difference of 25 ° C, MPa (kgf / cm²), no more 0.07 (0.7) Aerodynamic resistance, Pa (mm.WC) no more than 135 Combustion mirror area, m2 1,1 Overall dimensions of the boiler block with a furnace, no more Length, mm 2100 Width, mm 1400 Height, mm 1800
About company
Categories: Address:
Machinery, Industrial parts & tools, Industrial Equipments and Machines, General-purpose Equipments, Other equipments and machines, Electrical equipment, Industrial Equipment Parts, Industrial Instruments Russia, ул. Урицкого, д.8

Boiler plant Teploekspert, Irkutsk.

We produce hot water and steam boilers, furnaces, gas and liquid fuel boilers, modular boiler systems for fuel supply and slag removal, cyclones, draft machines and water treatment systems:
- hot water boilers KVR 0.15-KVR 4.0.

- coal-fired boilers with fire chambers TSHPM, TLPKh, ZP RPK, - KVm 0.8-KVm 4.0.
- hot water boilers for gas, diesel, fuel oil - Boiler KVA 0.47 - Boiler KVA 4.0

- steam boilers for gas, coal, wood, diesel, fuel oil, 300 kg / h, 500 kg / h, 700 kg / h, 1000 kg / h, KV-300 - 200,000 rubles, KV-500 - 390000 rubles, KV-700- 414000 rubles, KV-1000- 548000 rubles.
- wood-fired boilers KVR-0.23 KD, KVR-0.35 KD, KVR-0.47 KD, KVR-0.58 KD, KVR-0.7 KD, KZr-0.93 KD, KVr-1 , 28 cd.

- fire chambers TSHPM-0.8 - 300000 rubles, TSHPM-1.45-310000 rubles, TSHPM-1.5- 320 000 rubles, TSHPM-2.0 -330000 rubles, TSHPM-2.5 - 345000 rubles, spare parts of the furnace TShPM, TShPM gear rack segment, TShPM drive gear, TShPM support roller, TShPM lattice block, TShPM bunker, TShPM carriage, TShPM shura bar, -6500 rub, Ch 125 gearbox with engine. 3/1000, toothed rack TSHPM, pressure roller TShPM, pig-iron sleeve TShPM, firebox shield TShPM- 16000 rubles, steel section of the boiler Bratsk-6500 rubles, boiler water chamber Bratsk 37000 rubles, boiler nipple Bratsk

- fire chamber TLPH, fire chamber TLPH 1.1-4.25, fire chamber TLPH 1.1-3.5, fire chamber TLPH 1.1-3.0, fire chamber TLPH 1.4-4.0, fire chamber TLPH 1.87- 3.0, Fire chamber TLPH 1.87-4.25, Fire chamber TLPH 1.87-5.6, Fire chamber TLPH 1.87-6.5, Fire chamber TLP-0.8-3.32, Fire chamber TLP-0, 8-3.0 . Sprocket 23.5769.001, Gear wheel 23.5701.004, Half coupling 00.56.84.004, Rail 00.4260.001, Seal, Grate 23.1603.006 (081), Grate 23.1603.007 (084), Grate 23.1603.008 (080), Gearbox RPG- 1, The pin of the grate blade TLH, Canvas firebox TLH complete

- fire chambers TLZM Fire chamber TLZM 1.87 / 2.4, Fire chamber TLZM 1.87 / 3.0, Fire chamber TLZM 2.7 / 3.0, Fire chamber TLZM 2.7 / 4.0, grate 00.1603.032-01 ( T 24.06.001-01), grate 00.1603.032 (T 24.06.001), grate 00.1603.057 (T 24.06.004), grate 00.1603.058 (T 24.06.003, grate 00.1603.035 (T 328.01.03.00. 002), grate 00.1603.036 (T 328.01.03.00.001), pin 00.4101.084 (T 24.03.003, pin 00.4101.084-01 (T 68.03.001), full grate blade TLZM

- TCHZM fire chamber, TCHZM fire chamber 2.7-4.0, TCHZM fire chamber 2.7-5.6, TCHZM fire chamber 2.7-6.5, TCHZM fire chamber 2.7-8.0,

grate 00.1603.056 (6.30.26, grate 00.1603.038 (Т 220.13.001), holder 00.7003.004 (Т 220.13.002), holder 00.7003.005 (Т 220.13.003), holder 00.7003.006 (Т 220.13. 004), holder 00.7003.002 (T 9.05.002), holder 00.7003.001 (T 9.05.001), holder 00.7003.003 (6.30.2, roller roller 00.4609.003 (6.30.25)

- mechanical spreaders ZP-400, ZP-600, PMZ-400, PMZ-600. Spare parts for spreaders Sprocket 00.5786.008 (T67.00.066 m2), bearing housing 00.6927.007-00.1321.001 (T67.19.013M2) bearing cover 00.5081.001 (T67.19.008), bearing cover 00.6927.006, rotor blade (400 ) 00.1494.021-02 (Т 67.01.001М2-01), rotor blade (600) 00.1494.021 (Т 67.01.001М2) 600 tray 00.1601.022 (Т 67.00.001) 400 tray 00.1601.022-02 ( Т 67.00.001-01), regulating plate 00.1601.025 (Т67.24.001 М 2), regulating plate 00.1601.025-01 (67.24.001 М2-01), ZP-400 frame 00.1601.020-01 (Т 67.00. 005 M-1), frame ZP-600 00.1601.020 (T 67.00.005 M-2), Pulse variator T67.33.000 SB.

- battery cyclones BTs 2, BTs 2-4- (3 + 2), BTs 2-5- (3 + 2, BTs 2-5- (4 + 2), BTs 2-6- (4 + 2), BTs 2-6- (4 + 3), BC 2-7- (5 + 3).

- Battery cyclones BTs-259. BTs-259- (3x2), BTs-259- (3x3), BTs-259- (4x3), BTs-259- (4x4) rub, BTs-259- (4x5), BTs-259- (6x4), BTs -259- (6x5), BTs-259- (6x6), BTs-259- (6x7), BTs-259- (6x8).

Contact supplier
Supplier:
"Узлегпром"
Write to us, we are online!